NS Series Test Chambers
Corrosion resistance test for products after treated by plating, anodized, spraying, and anti-rust. High temperature resistant material to ensure log-term use.
The inside and the outside of the chamber are made of high temperature and high humidity resistance anti-corrosive high grade PVC.
Technical Parameters for Salt Corrosion Chamber | Dati tecnici della Camera per prove di Temperatura e Altitudine | Dati tecnici della Camera per prove di Temperatura e Altitudine | ||||
---|---|---|---|---|---|---|
Model | NS series | |||||
150 | 250 | 750 | 010 | 016 | 020 | |
Interior size(cm) | 47*59*40 | 64*100*50 | 5*110*50 | 100*130*60 | 90*160*72 | 100*200*800 |
Exterior size(cm) | 62*140*105 | 81*180*118 | 92*190*120 | 120*220*140 | 130*250*160 | 142*300*185 |
Temp. Range | +20ºC~+60ºC | +20ºC~+60ºC | +20ºC~+60ºC | +20ºC~+60ºC | +20ºC~+60ºC | +20ºC~+60ºC |
Temp. uniformity | ±2.0ºC | ±2.0ºC | ±2.0ºC | ±2.0ºC | ±2.0ºC | ±2.0ºC |
Temp. constancy | ±0.5ºC | ±0.5ºC | ±0.5ºC | ±0.5ºC | ±0.5ºC | ±0.5ºC |
Spray quantiity | 1.0-2.0 ml / 80 cm2/hr | 1.0-2.0 ml / 80 cm2/hr | 1.0-2.0 ml / 80 cm2/hr | 1.0-2.0 ml / 80 cm2/hr | 1.0-2.0 ml / 80 cm2/hr | 1.0-2.0 ml / 80 cm2/hr |
Spray type | Continous/Periodic | Continous/Periodic | Continous/Periodic | Continous/Periodic | Continous/Periodic | Continous/Periodic |
Brine Temperature | 35°C±1.0ºC | 35°C±1.0ºC | 35°C±1.0ºC | 35°C±1.0ºC | 35°C±1.0ºC | 35°C±1.0ºC |
PH | NSS(6.5-7.2);AASS CASS(3.1-3.3) | NSS(6.5-7.2);AASS CASS(3.1-3.3) | NSS(6.5-7.2);AASS CASS(3.1-3.3) | NSS(6.5-7.2);AASS CASS(3.1-3.3) | NSS(6.5-7.2);AASS CASS(3.1-3.3) | NSS(6.5-7.2);AASS CASS(3.1-3.3) |
Interior material | Glass fiber reinforced plastics | Glass fiber reinforced plastics | Glass fiber reinforced plastics | Glass fiber reinforced plastics | Glass fiber reinforced plastics | Glass fiber reinforced plastics |
Exterior material | Glass fiber reinforced plastics | Glass fiber reinforced plastics | Glass fiber reinforced plastics | Glass fiber reinforced plastics | Glass fiber reinforced plastics | Glass fiber reinforced plastics |
Ambient Environment | T. range: +5ºC~+35ºC, H. range: 10% to 98%, Pressure: 86~106kPa | T. range: +5ºC~+35ºC, H. range: 10% to 98%, Pressure: 86~106kPa | T. range: +5ºC~+35ºC, H. range: 10% to 98%, Pressure: 86~106kPa | T. range: +5ºC~+35ºC, H. range: 10% to 98%, Pressure: 86~106kPa | T. range: +5ºC~+35ºC, H. range: 10% to 98%, Pressure: 86~106kPa | T. range: +5ºC~+35ºC, H. range: 10% to 98%, Pressure: 86~106kPa |
Safety device (standard) | Over pressure, over heat and current discharge protection | Over pressure, over heat and current discharge protection | Over pressure, over heat and current discharge protection | Over pressure, over heat and current discharge protection | Over pressure, over heat and current discharge protection | Over pressure, over heat and current discharge protection |
Over load fuse protection | Over load fuse protection | Over load fuse protection | Over load fuse protection | Over load fuse protection | Over load fuse protection | |
Wiring method | 230V 50HZ | 230V 50HZ | 230V 50HZ | 400V 50HZ | 400V 50HZ | 400V 50HZ |